We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Thermo Chiller.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Thermo Chiller - List of Manufacturers, Suppliers, Companies and Products

Thermo Chiller Product List

1~2 item / All 2 items

Displayed results

Thermochiller "HRS400 Series"

Adopts a submersible pump (without mechanical seals)! The operating status of the chiller can be monitored on a single screen.

The HRS400 Series is a standard type of thermochiller. It is air-cooled and has a cooling capacity of 38 kW, with a set temperature range of 5 to 35°C. The maximum ambient temperature for use is 45°C, and the temperature stability is ±0.1°C, with a waterproof structure rated IPX4. Additionally, the adoption of a touch panel has improved the product's settings, operation, and visibility. 【Specifications (partial)】 ■ Cooling capacity: 38 kW ■ Power supply ・3-phase 380–415V (50Hz/60Hz) ・3-phase 460–480V (60Hz) ■ Set temperature range: 5–35°C ■ Maximum ambient temperature for use: 45°C *For more details, please download the PDF or feel free to contact us.

  • Chiller

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Improving productivity and efficiency, equipment review (2) [Case studies for problem-solving]

The defect occurrence rate has decreased! Replacement orders through testing with the actual SMC thermochiller loan.

At Equipment Manufacturer N, they have traditionally used chiller units from other manufacturers and were considering an update due to equipment lifespan. SMC's thermal chiller is available for actual machine loan, so we brought the "HRS050-A-20" with specifications equivalent to the existing unit for testing. After confirming that there were no issues with the replacement, we received positive feedback as the temperature stability of ±0.1°C significantly reduced the failure rate compared to the previous chiller unit. 【Case Study】 ■ Equipment Manufacturer N ■ Concerns and Consultation - Considering an update due to the equipment lifespan of chiller units from other manufacturers ■ Proposal and Results - Conducted a test with an actual machine loan of SMC's thermal chiller - The failure rate significantly decreased compared to the previous chiller unit *For more details, please feel free to contact us.

  • Chiller
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration